INtime SDK Help
ntxSendRtMessageRSVP
INtime SDK v6 > About INtime > INtime Kernel > Ports > ntxSendRtMessageRSVP

Sends the request phase of a transaction and allocates a storage for the response part of the transaction.

NTXXID ntxSendRtMessage(
    NTXHANDLE hPort,
    NTXGENADDR *pAddress,
    BYTE *pControl,
    DWORD dwControlLength,
    LPVOID pData,
    DWORD dwDataSize,
    LPVOID pReply,
    DWORD dwReplySize,
    DWORD dwTransmissionFlags
);

Parameters

hPort
The port where this message originates.
pAddress
The address of the destination port. This can be NULL if the port is connected, or if the service can accept messages itself.
pControl
The control message to send. There is always a control message.
dwControlLength
The size of the control message.
pData
The data part of the message, or NULL for control messages.
dwDataSize
The size of the data part of this message.
pReply
The buffer in which the data part of the reply message will be stored.
dwReplySize
The size in bytes of the posted reply buffer.
dwTransmissionFlags
These are the same as ntxSendRtMessage.

Return Values

The transaction ID associated with this message.
Success.
BAD_TRANSACTION_ID
Failure. To determine the status, call ntxGetLastRtError.

Status

E_OK 0x0000
No exceptional conditions occurred.
E_CONTEXT 0x0005
One of these conditions exist:
  • The port is an anonymous sink port.
  • The service does not support RSVP transactions.
E_EXIST 0x0006
The port is already being deleted.
E_NOT_CONFIGURED 0x0008
The service does not have a SendMessage handler.
E_TRANSMISSION 0x000B
One of these conditions exist:
  • The destination port does not exist or is invalid (short circuit).
  • A hardware error occurred during transmission.
E_INVALID_ADDR 0x00E2
The address parameter is not valid.
E_RESOURCE_LIMIT 0x00E6
Insufficient control buffers are available.
E_DISCONNECTED 0x00E9
The destination port is connected to another port.
E_TRANS_LIMIT 0x00EA
The transaction limit for either the port or the service has been exceeded.
E_UNBOUND 0x00EB
The port has not been bound.
E_TYPE 0x8002
The handle supplied is not for a port object.
E_PARAM 0x8004
One of these conditions exist:
  • An address parameter was supplied for a non-addressed service.
  • The control message length supplied is too great.
E_NUC_BAD_BUF 0x80E2
One of these conditions exist:
  • The control message pointer was invalid.
  • The data pointer was invalid.
  • The RSVP pointer was invalid.
E_LOCATION
The RT client on which the port was created is now invalid.
E_NTX_INTERNAL_ERROR
The DLL could not contact the RT kernel to complete the request.
Note:   Other status values may be generated by the service-specific SendMessage handler.

Requirements

Versions Defined in Include Link to
INtime 3.0 intime/nt/include/ntx.h ntx.h ntx.lib
INtime 4.01 (for 64-bit Windows) intime/nt/include/ntx.h ntx.h ntx64.lib

See Also

Port system calls, ntxSendRtMessage, SendMessage